Understand raw and adjusted measurements

For most gauges, the app keeps two values for each measurement: the raw measurement and the adjusted measurement. This page explains what they represent, gauge by gauge, and how to choose the one used as the reference.

Two values for the same measurement

  • The raw measurement is the value as it was taken: read on the gauge and entered in the app, or sent by the sensor of a wireless gauge.
  • The adjusted measurement is that same value, corrected or converted by the app. Depending on the gauge, it compensates for the expansion of the gauge with temperature, or it turns the reading into a more meaningful quantity (a displacement in mm, a position…).

In both cases, the change is counted from the first measurement of the gauge: it is the difference between each measurement and this first measurement that tells you about the crack.

Why correct for temperature

A gauge gets longer when it is hot and shorter when it is cold, like any material. Without correction, a reading taken in mid-summer can differ by a few hundredths to almost two tenths of a millimetre from a winter reading, even though the crack has not moved.

The adjusted measurement removes this effect: the app compares the temperature of each reading with that of the first measurement, and corrects the value with the expansion coefficient of the gauge. For example, a G1 gauge read at 19 °C shows 5.7 mm raw and 5.8 mm adjusted.

Where the temperature comes from:

  • Wireless gauges: a sensor built into the gauge measures the temperature on site, with each measurement. You have nothing to enter.
  • Manually read gauges: enter the temperature with each reading (see Record a G1 or G1+ reading). If you allow geolocation, the app suggests it automatically, from the local weather data. This value does not take into account the exact location of the gauge: indoors, or on a south-facing or north-facing façade, the temperature can be quite different. Check it and correct it if necessary.

If you do not want to take temperature into account, simply enter 0 for every reading: the adjusted measurement is then equal to the raw measurement.

What the app calculates, gauge by gauge

Gauge Adjusted measurement Default reference
G1, G1.1, G1.2 Measurement corrected for the expansion of the gauge (about 0.009 mm per °C) Adjusted measurement
G1+ Measurement corrected for expansion (about 0.007 mm per °C) Adjusted measurement
G2 Measurement corrected for expansion (about 0.013 mm per °C) Adjusted measurement
G1.5 (carbon fibre) Measurement corrected for expansion (about 0.0005 mm per °C: the gauge hardly expands at all) Raw measurement
G3 Change in misalignment: the deviation read multiplied by the coefficient of the gauge (2 by default, adjusted according to the rod length) Adjusted measurement
G5 Change in tilt in mm at the end, according to the height of the wall or the length of the cantilever Adjusted measurement
E1 X (and Y) position calculated from the measured distances Adjusted measurement
R1, R20… Measurement corrected for the expansion of the gauge (about 0.003 mm per °C) Raw measurement
R5 Tilt angles corrected for the drift of the sensor with temperature *; displacement in mm if you have entered the height of the wall Raw measurement
R2, R2.P, R10 No adjusted measurement: only the raw measurement exists —

* R5: the tilt is measured by an electronic sensor (MEMS), whose reading varies slightly with temperature. This is normal for this type of sensor. Each sensor is calibrated to determine its own correction coefficient, which the app applies to calculate the corrected tilt angles.

For G3, G5 and E1 gauges, first enter the parameters of the gauge with Set parameters: they are used for the calculation.

Choose the reference value

The reference value is the one the app uses for:

  • the summary of the gauge: the deviation between the first and the last measurement, and the maximum amplitude;
  • the curve displayed by default in the chart;
  • the value suggested for the alert threshold (see Set an alert threshold).

On the gauge page, choose Raw measurement or Adjusted measurement next to Reference measurement for G1 gauges (1). The summary is updated immediately (2).

The reference value and the gauge summary

You can also use the ⋮ menu of the gauge, then Choose the reference: the Select reference value window offers the type of the gauge and its variants (here G1, G1.1 and G1.2). Tick Raw measurement or Adjusted measurement, then click Validate. Show other gauge types gives access to all types. From a place, the ⋮ menu offers Choose the references.

The Select reference value window

Display both values

In the list of measurements: click Select columns, then tick Raw measurement and Adjusted measurement, as well as their deviations from the first measurement. Click Validate. The choice is kept for this type of gauge.

The Values to display window

In the chart: turn on the Raw measurement and Adjusted measurement switches to overlay the two curves. Here, on a G1 gauge, they stay within one or two tenths of a millimetre of each other: this difference is the effect of temperature on the gauge. To display a specific period, use Configure chart.

The raw and adjusted curves in the chart